Time and Event Sync all PCs

From MXWendler Wiki
Revision as of 13:16, 1 October 2019 by Behrooz (talk | contribs)
Jump to navigation Jump to search

This applies to MXWendler version 4.2 and above

Task

Pooling MXWendler systems via time synchronization.

Tests to do before starting MXWendler

  • Can you ping all the computers from one host?
  • Can you ping back?
  • Does your router/switch allow broadcasting?
  • Are the firewalls turned off?
  • Does the admin account have a password ( Windows 7)?

Solution

1. Turn on OSC receiving for every machine on port 7000.

2. Create a simple OSC testing application with eg. PD and send some commands to *any machine* from *any machine*.

3. Turn on 'Broadcast and receive time' for every machine. all machines will send their time until they receive a packet from a machine with the lower IP, then they switch to receiving.

4. Broadcast to the subnet: 192.168.1.255 ( subnet may have a different IP ).

5. Broadcast to the ports where the machines are listening ( 7000 ).

Important: sometimes Windows 7 does not allow broadcasting, then address the other machine with its IP directly ( eg. 192.168.1.23 instead of 192.168.1.255 ).