Difference between revisions of "Windows XP + e:cue"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
'''This applies to Windows 7 and MXWendler version 4.2 and above''' | '''This applies to Windows 7 and MXWendler version 4.2 and above''' | ||
− | ''Problem | + | '''Problem''' |
− | |||
− | + | If you use e:cue programmer 5.2 ( and possibly other versions ) to send dmx data to MXWendler,some values drop to 0.0 every two seconds, or stay at 0.0 for two second and jump to the desired value for a short time. | |
− | |||
− | ''Solution/Workaround | + | '''Reason''' |
− | + | ||
− | + | e:cue sends wrong values | |
+ | |||
+ | '''Solution/Workaround''' | ||
+ | |||
+ | e:cue supports sending up to 4 universes. <br> | ||
+ | If you use different universes, the problem appears, if you use the same universe 4 times the problem disappears. |
Revision as of 15:21, 8 April 2019
This applies to Windows 7 and MXWendler version 4.2 and above
Problem
If you use e:cue programmer 5.2 ( and possibly other versions ) to send dmx data to MXWendler,some values drop to 0.0 every two seconds, or stay at 0.0 for two second and jump to the desired value for a short time.
Reason
e:cue sends wrong values
Solution/Workaround
e:cue supports sending up to 4 universes.
If you use different universes, the problem appears, if you use the same universe 4 times the problem disappears.