Time and Event Sync all PCs
This applies to all different OS and MXWendler version 4.2 and above
Task
Pooling MXWendler systems via time synchronization.
Tests to do before starting MXWendler
- Can you ping all the computers from one host?
- Can you ping back?
- Does your router/switch allow broadcasting?
- Are the firewalls turned off?
- Does the admin account have a password ( Windows 7)?
Solution
1. Turn on OSC receiving for every machine on port 7000.
2. Create a simple OSC testing application with eg. PD and send some commands to *any machine* from *any machine*.
3. Turn on 'Broadcast and receive time' for every machine. all machines will send their time until they receive a packet from a machine with the lower IP, then they switch to receiving.
4. Broadcast to the subnet: 192.168.1.255 ( subnet may have a different IP ).
5. Broadcast to the ports where the machines are listening ( 7000 ).
Important: sometimes Windows 7 does not allow broadcasting, then address the other machine with its IP directly ( eg. 192.168.1.23 instead of 192.168.1.255 ).
For more information on time and event syncing PCs check 'Tutorial Time-sync and sending IO Commands over OSC Protocol'.